Chrom Z Chromogenic Substrate Assays
Discovery Diagnostics is the Canadian
distributor for Helena Laboratories, Chrom Z Chromogenic Substrate
Assays
All
Chrom Z kits can be used in endpoint determinations on any spectrophotometer
at 405 nm. Recommended is the PACKS-4 semi-automated, kinetic method
which allows use of smaller sample and reagent volumes.
See Related
Products:
Packs 4 ® Platelet Aggregation Chromogenic Kinetics System
Chrom
Z Chromogenic Substrate Assays
| Cat.
No. |
Item |
5240
|
Chrom Z Antithrombin
III Kit, 60 - 150 tests
Thrombin Reagent, 6 x 2.0
mL
AT Substrate, 6 x 2.0 mL
AT Buffer, 6 x 2.0 mL
Antithrombin
III Chromogenic Substrate Assay
Chrom Z Antithrombin III
is a simple two-stage method for quantitative determination
of AT III. Thrombin is first added to a plasma dilution
containing excess heparin. After incubation, a thrombin-specific
chromogenic substrate is used to determine residual thrombin
which is inversely proportional to AT III concentration.
|
| Cat.
No. |
Item |
5241
|
Chrom
Z Factor VIII:C Kit, 60 - 150 tests
Factor IXa Reagent, 6 x 2.0 mL
Factor X Reagent, 6 x 2.0 mL
Factor Xa Substrate, 6 x 2.0 mL
Plasma Dilution Buffer, 6 x 2.5
mL
Factor VIII:C Chromogenic Substrate Assay
The Chrom Z Factor VIII:C assay is useful in diagnosing
Hemophilia A, monitoring therapy, and QC of Factor VIII
concentrate and cryoprecipitate products. After activation
by thrombin, F.VIII:C acts as a cofactor in conversion
of F.X to F.Xa in the presence of F.IXa, calcium and phospholipids.
F.Xa generated is measured using a specific chromogenic
substrate and is directly proportional to F.VIII:C in
the sample.
|
| Cat.
No. |
Item |
5242
|
Chrom
Z Heparin Kit, 60 - 150 tests
Factor Xa Reagent, 6 x 2.0 mL
Factor Xa Substrate, 6 x 2.0 mL
Antithrombin III, 6 x 1.5 mL
Heparin Chromogenic
Substrate Assay
Chrom Z Heparin is for quantitative determination of therapeutic
heparin (standard and low molecular weight) in human plasma.
In presence of F.Xa and excess AT III, the rate of F.Xa
inhibition is directly proportional to heparin concentration.
Residual F.Xa activity, measured with a F.Xa-specific
chromogenic substrate, is inversely proportional to heparin
concentration.
|
| Cat.
No. |
Item |
5244
|
Chrom Z Plasminogen
Kit, 60 - 150 tests
Streptokinase Reagent, 6 x 2.0
mL
Plasmin Substrate, 6 x 2.0 mL
PLG Buffer, 6 x 2.0 mL
Plasminogen Chromogenic
Substrate Assay
Chrom Z Plasminogen is useful
in detecting congenital and acquired deficiencies, particularly
DIC, and in monitoring thrombolytic therapy. Specificity
of the Chrom Z method is ensured by use of a chromogenic
substrate specific for the streptokinase-plasminogen complex
or plasmin, and by use of streptokinase which has no proteolytic
activity by itself and is known to activate only plasminogen
in human plasma.
|
| Cat.
No. |
Item |
5243
|
Chrom
Z Protein C Kit 60 - 150 tests
Protein C Activator, 6 x 2.0 mL
Protein C Substrate, 6 x 2.0 mL
Substrate Additive, 1 x 3.0 mL
Protein C Chromogenic
Substrate Assay
This Chrom Z assay is for quantitative determination of
Protein C (PC). When activated, PC inhibits coagulation
by inactivating F.Va and F.VIIIa, and has also been shown
to stimulate fibrinolysis. PC in plasma is rapidly and
selectively activated by using snake venom. Activated
PC is detected by monitoring hydrolysis (release of pNA)
of a PC-specific chromogenic substrate.
|
Canadian Customers if you
wish to speak to a sales representative or customer service, please
call Toll Free within Canada: 1-888-883-9101. Outside Canada, click
here for ordering information.
|
|
|
|


 
|