Nanoduct Neonatal Sweat Analysis System Early Cystic Fibrosis Diagnosis Discovery Diagnostics, Canadian distributor for Wescor's Nanoduct Neonatal Sweat Analysis System Infant CF Diagosis
Discovery Diagnostics Laboratory Test Kits Diagnostic Equipment Distributor

Nanoduct™ Neonatal Sweat Analysis System
Early Cystic Fibrosis Diagnosis

Discovery Diagnostics, Canadian distributor for Wescor's Nanoduct Neonatal Sweat Analysis System for early laboratory diagnosis of cystic fibrosis.


Nanoduct Neonatal Sweat Analysis SystemThe Nanoduct System provides iontophoresis for 2 ½ minutes followed by continuous flow conductivity analysis on only 3 microliters of sweat. The Nanoduct System also provides the initial sweating rate. While Nanoduct is designed for neonates, it works equally well on patients of any age.

Wescor presents a significant breakthrough in sweat testing that for the first time makes possible reliable CF diagnosis in the first days of life. Early diagnosis allows timely intervention and more effective therapy to improve quality of life for CF patients.







Hemotology Slide Stainer Cytocentrifuge Product Details
Unique continuous-flow analysis eliminates a separate collection phase and analyzes pristine samples within minutes. The possibility of human error is minimized. In addition, the system provides automatic display of initial sweating rate and automatic averaging of conductivity. With shorter stimulation time and minuscule sample requirement (only 3 microliters of sweat), you can have reliable results in only a few minutes.

Nanoduct's miniaturized components fit easily on neonates. It is a complete integrated diagnostic system that simplifies the procedure not only for neonates but for patients of any age.

Nanoduct incorporates the classic method of inducing sweat by pilocarpine iontophoresis. The pilocarpine is carried into the dermis of the patient from improved Pilogel® Iontophoretic discs via a controlled DC electrical current supplied by the Nanoduct Inducer/Analyzer. This is followed by continuous flow analysis of sweat electrolyte concentration using the unique conductivity sensor.

Simple to use on Neonates
Infant size electrodes slip easily into the holders, thus greatly simplifying electrode and sensor attachment, as attested by clinical trials


Hemotology Slide Stainer Cytocentrifuge Specifications
Sweat Induction Control Current profiled for patient comfort. For use with Pilogel Iontophoretic discs and with multiple fail-safe features to limit current even in failure mode.  Nominal current is 0.5 mA for 2.5 minutes.
CURRENT LIMIT (Failure Mode) Maximum failure mode current limited to 5 mA with fresh battery.
SWEAT ANALYSIS Sweat Conductivity with readout expressed as mmol/L (equivalent NaCl).
RANGE 0 to 200 mmol/L (equivalent NaCl).
INSTRUMENT LINEAR ERROR 1% or less from 75 to 110 mmol/L (equivalent NaCl).
INITIAL SWEATING RATE READING 0.1 to 10 g/m2/min.
CALIBRATION Single point automatic calibration at 80 mmol/L (equivalent NaCl).
POWER SUPPLY One 9.0 volt Lithium battery (Alkaline battery can be used). 100 milliwatt power use during operation. Lithium batteries are good for approximately 300 tests.
READOUT 128 x 64 dot graphic display with multi-lingual support.
AUDIO SIGNALS ALERT and ALARM audible signals.
KEYBOARD ON, OFF, SELECT, and ENTER keys.
CONNECTION 5 pin connector to mate with induction/conductivity cell cable.
OPERATING TEMPERATURE 13 to 30 °C.
STORAGE TEMPERATURE 0 to 60 °C.
REGULATORY Meets EN 61326 Standards for EMC compatibility. Meets IEC 60601 standards for safety. Manufactured under Wescor’s quality system (ISO 9001).
PHYSICAL Housed in a portable carrying case with storage compartment for supplies and handle for ease of carrying.
HEIGHT X WIDTH X DEPTH: 16 cm x 23 cm x 33 cm.
WEIGHT Less than 2.25 kg.


Ordering Information Hematology Slide Stainer Cytocentrifuge
Cat. No. Item
7120 Aerospray hematology Slide Stainer/Cytocentrifuge
Includes the following

  • AC-028 Slide Carousels (2)
  • AC-041 Drain Tubing (1 length)
  • AC-074 Nozzle Maintenance Kit (1)
  • SS-124 (1)
  • User's Manual
  • One-Year Parts & Labor Warranty
Accessories & Supplies
AC-081
Nanoduct Calibration Standard Plate
AC-113 Power Supply
310898-01 Patient Simulator Cleaning Adaptor
42-0125 Tweezers
42-0126 Hemostat
SS-043 Nanoduct Supply Kit (for 6 sweat tests; contains Pilogel® Disc for Nanoduct (12 each), Sensor Cell (6 each)).
SS-150 Sweat Controls 1, 2, 3, 0.75 mL ampule (package of 36: 12 each of Control 1, 2, and 3) Sweat Control 1 molarity is approximately 40 mmol/L. Sweat Control 2 molarity is approximately 70 mmol/L. Sweat Control 3 molarity is approximately 130 mmol/L. Each Sweat Control lot has a specific control value and range.
310565-01 Nanoduct Sensor Cell
SS-220 Waste Collection Pads
Replacement Parts
110751 Attachment Strap Retainer Post
17-0815 Case Latch
321502-01 Display Assembly
121419-01 Electrode Attachment Strap Small
121421-01 Electrode Attachment Strap, Large
121420-01 Electrode Attachment Strap, Medium
310806-02 Negative Black Electrode Holder
310806-01 Positive Red Electrode and Sensor Cell Holder
321424-01 Red/Black Electrode Cable Set
Manuals
M2188-2 Nanoduct Neonatal Sweat Analysis System User's Manual
PRINT-0175-01 Nanoduct Patient Simulator User's Manual
Factory Service
FS-451 Nanoduct Calibration Plate Verification


Canadian Customers if you wish to speak to a sales representative or customer service, please call Toll Free within Canada: 1-888-883-9101. Outside Canada, click here for ordering information.

Nanoduct Neonatal Sweat Analysis System
Downloadable Files:
  Nanoduct Neonatal Sweat Analysis System Brochure
PDF Format (665 kb)



Order Hemotology Stainercontact Discovery Diagnostics

Sales Outside Canada
Site Last Updated July 7, 2008
© 2008, Discovery-Diagnostics, All Rights Reserved
Privacy | Trademark Information
Our Company | Sales & Support | Site Map | Home
Nanoduct Neonatal Sweat Analysis System Early Cystic Fibrosis Diagnosis Discovery Diagnostics, Canadian distributor for Wescor's Nanoduct Neonatal Sweat Analysis System Infant CF Diagosis