Safe-T-Vue® Non-Reversible Blood
Temperature Indicator
For Blood Safety Management
Discovery Diagnostics is the Canadian
distributor for William Laboratories Safe-T-Vue®, a non-reversible
blood temperature indicator for blood safety and blood management
for transporting and reissuing blood.

Temperature, not time, is the Standard
for Blood Management. Saf-T-Vue needs to be refrigerated for 24 hrs
prior to use.
Safe-T-Vue® improves quality assurance in two ways:
1. It specifically
shows whether the blood may be reissued when returned, (*Standards,
AABB), and 2. It promotes the
requirements of accountability during its transport.
Safe-T-Vue® Temperature Indicators
are packed as boxes of 50 Indicators. Each box is stamped with
its lot number and expiration date.
Safe-T-Vue® Technical Information
1. Store Safe-T-Vue®
in blood refrigerator at least 24 hours prior to use.
2. Take blood and
Safe-T-Vue® out of the refrigerator at the same time.
3. Position the Safe-T-Vue®
directly on the plastic of the blood bag in an area that has the largest
volume
of blood.
In just 10 seconds, each blood bag is ready for transport. The white
center indicates a safe temperature below 10°C. If blood bags
are returned and the Safe-T-Vue center is still white you can re-refrigerate
with the Indicator attached and later reissue.
*American Association of Blood
Banks Standards for Blood Banks and Transfusion, 19th Edition, Washington,
D.C. ---Reissue of Blood H4.100 "blood that has been returned
to the blood bank or transfusion service shall not be reissued unless
the following conditions have been observed:... H4.120. The blood
has not been allowed to warm above 10 degrees centigrade or to cool
below 1 degree centigrade during storage or transportation."
|
Safe-T-Vue® Publications
for Download
RBC Audit from Kingston General Hospital,
Kingston, ON (PDF File 1.72 MB)
Use of Indicators to Verify Maintenance
of Appropriate Temperatue for Returned Red Cells
Royal Alexandra Hospital, Misericordia Hospital, Dynacare
Kasper Medical Laboratories, Edmonton, Alberta (PDF 1.03
MB)
Poster Presentation from Royal Alexandra
Hospital, Misericordia Hospital, Dynacare Kasper Medical Laboratories,
Edmonton, Alberta (PDF 806 KB)
Irreversible
Temperature Indicators as an Audit Tool for Assuring Blood
Product Temperature Control Emory School of Medicine, Atlanta
Georgia (PDF 316 KB)
Poster Presentation - Emory School
of Medicine, Atlanta Georgia (PDF 748 KB)
FDA Standards (PDF 246 KB)
Storage vs. Transport FDA Interpretation
(PDF 176 KB)
Red Cross Job Aid - Packing RBC's
and Whole Blood (PDF File 152 KB)
|

| Cat. No. |
Item |
| WL-7201-50 |
Safe-T-View non reversible
temperature indicator - box/50. |
Canadian Customers if you
wish to speak to a sales representative or customer service, please
call Toll Free within Canada: 1-888-883-9101. Outside Canada, click