Vapro® Vapor Pressure Osmometer
Discovery Diagnostics, Canadian distributor
for Wescor's Vapro® Vapor Pressure Osmometer for osmotic measurement
of fluids, viscous samples & tissue specimens
The Vapro® Vapor
Pressure Osmometer brings unprecedented simplicity, convenience, and accuracy to the routine determination of osmolality to help meet the demands placed on today’s clinical laboratory.

Auto-calibration, a self cleaning thermocouple, self-diagnostics, statistical analysis, and computer interface/printout capabilities make the Vapro osmometer a must for any busy laboratory. The small sample requirement allows you to assay hard-to-get or expensive samples using the superior characteristics of the vapor pressure method.
Why Vapor Pressure? “
Vapor pressure measurement is the fastest and easiest method of determining osmolality, and the thermodynamic limitations of vapor pressure osmometry are least restrictive. For these reasons, vapor pressure osmometry is the method of choice for most fluids in biology and medicine in which water is the solvent.”
The vapor pressure method determines osmolality at room temperature with the sample in natural equilibrium. This pre- cludes cryoscopic artifacts due to high viscosity, suspended particles, or other conditions that can interfere with freezing point determinations, giving Vapro a much broader range of error-free applications.
The fundamental advantages of vapor pressure osmometry are now embodied in the most intelligent osmometer ever produced. Wescor’s Vapro offers an intuitive approach that frees you from intensively “managing” an instrument
Features
Menu Driven
Streamlined user interface for quick access to menu items and common functions.
User-Selectable Measurement Modes: Single sample; Auto Repeat Mode for repeat measurements of the same sample; Averaging Mode for precision measurements; Delayed Start Mode for samples requiring longer equilibration times.
Four user-selectable languages (English, French, German, Spanish).
Superb Accuracy
Unsurpassed by any other method, error is less than 1% in the clinical range.
Self Cleaning
Self-cleaning thermocouple reduces maintenance and improves performance.
Easy Calibration
A push of a button automatically sets the calibration parameters.
Economical
Low initial cost, no expensive proprietary supplies
Trouble-free Self Diagnostic Operation
Few moving parts, no mechanical adjustments, no mechanical breakdowns.
Automated circular sample slide and chamber locking operation, which places all the controls on the front panel.
Built in clock records and displays a date code for each sample result.

| Sample Volume |
10 µL nominal
Other accessory sample volumes;
2 µL using AC-064 sample holder and approximately 60 µL using AC-065 sample holder |
| Measurement Range |
Typically 20 to 3200 mmol/kg
(up to 3800 mmol/kg with extended range osmometer) @ 25° C ambient |
| Measurement Time |
90 seconds |
| Resolution |
1 mmol/kg |
| Repeatability |
< 2
mmol/kg Standard Deviation between 20 to 1000 mmol/kg;
< 5% of reading between 1000 and 3200 mmol/kg; while operating between 20 and 25 ° C |
| Linearity |
+ 5% of reading over total range and +1% of reading over calibrated range while operating between 20 and 25 ° C |
| Calibration |
Automatic using Opti-Mole™ osmolality standards |
| Readout |
240 x 128 pixel backlit LCD |
|
Operating Temperature
|
This device has been designed for indoor use only between 15° and 37° C with a maximum relative humidity of 85%. For use at elevations up to 2000 meters (instrument should be at stable temperature before calibrating) |
| Storage Temperature |
0 to 60° C |
| Serial Output |
RS-232 (ASCII format) USB - Slave |
Electrical
Line Voltage: 100 to 240 V nominal,
50 to 60 Hz Transient
Power: 40 Watts Maximum
Fuses: 2 required5 x 20 mm time delay type T-1 ampere at 250 volts |
| Size (H x W x D) |
20 cm (8:0 x 28 cm (11") x 36 cm (14") |
| Weight |
6.8 kg (15lbs) |

| MODEL 5600 |
VAPRO Vapor Pressure Osmometer |
| MODEL 5600XR |
VAPRO Vapor Pressure Osmometer Extended Range |
| Accessories for Vapro 5600 |
| AC-062 |
Sample holder,7 x 1.25mm for 5520, 5600 |
| AC-063 |
Sample holder, 2 uL, for 5520, 5600 |
| AC-064 |
Sample holder,7 x 2.5 mm for 5520, 5600 |
| AC-065 |
Sample holder,9.5x4.5 mm for 5520, 5600 |
| AC-177 |
Seiko printer, cable, power supply (9600 baud) |
| AC-174 |
TC HEAD ASSY,0-3200 mmol/kg,VAPRO 5600 |
| AC-011 |
Hex Driver, 9/64 inch, screwdriver handle |
| AC-036 |
Forceps, 5 inch, stainless steel |
| AC-037 |
Micropipettor, 10 uL |
| AC-049 |
Printer Cable for Vapro |
| AC-061 |
Ampule Organizer for Osmolality Standards |
| AC-176 |
VAPRO LAB REPORT SOFTWARE |
| AC-172 |
Paper roll for Seiko Instruments printer |
| Supplies for Vapro 5600 |
| SS-238 |
Desiccant filter cartridge for Vapro 5600 |
| SS-239 |
Waste reservoir for Vapro 5600, Colloid 4500 |
| SS-240 |
Supply reservoir for Vapro 5600, Colloid 4500 |
| SS-039 |
Osmocoll HNL osm. ctrl. refs. 6 1mL vials (2 EA) |
| SS-026 |
Blow Clean inert dusting gas, 284 gram canister |
| SS-033 |
Sample Discs (5000 ea) |
| SS-036 |
Pipettor Tips (1000 ea) |
| OA-010 |
Opti-Mole 100 mmol/kg Osmolality Stds .4mLx60 |
| OA-029 |
Opti-Mole 290 mmol/kg Osmolality Stds .4mLx60 |
| OA-100 |
Opti-Mole 1000 mmol/kg Osmolality Stds .4mLx60 |
| SS-003 |
Cleaning Solution for thermocouples, 60 mL |
| SS-006 |
Deionized Water, 60-mL bottle, with dropper |
| SS-223 |
T/C Cleaning Solution w/Anionic Detergent,60mL |
| SS-025 |
Osmocoll N COP calibrtr, osmolality control refs. |
| Repair/Replacement Parts for Vapro 5600 |
| RP-453 |
Manual, service, CD-ROM, Vapro 5600 |
| RP-429 |
POWER SUPPLY, 5600 |
| RP-430 |
ELECTRONIC MODULE, 5600 |
| RP-431 |
TC HEAD EXCHANGE,0-3200 mmol/kg,VAPRO 5600 |
| Core Charge - call for price |
| RP-432 |
TC HEAD CABLE ASSEMBLY 5600 |
| RP-445 |
Manual, application, for Vapro 5600 |
| Accessories for Vapro 5520 |
| AC-112 |
Seiko printer, cable, power supply for 5520 |
| AC-115 |
Lab Report Software Utility Kit |
| AC-172 |
Paper roll for Seiko Instruments printer |
| Supplies for Vapro 5520 |
| SS-039 |
Osmocoll HNL osm. ctrl. refs. 6 1mL vials (2 EA) |
| Repair/Replacement Parts for Vapro 5520
|
| RP-173 |
TC Exchange,5520 (0-3200 mmol/kg), w/ core charge |
| RP-174 |
TC Exchange, 5520 (>3200 mmol/kg), w/ core charge |
Canadian Customers if you
wish to speak to a sales representative or customer service, please
call Toll Free within Canada: 1-888-883-9101. Outside Canada, click
here for ordering information.
|
|
|
|
Downloadable Brochure:
5600-Vapro
Vapour Pressure Osmometer - PDF Format (442 kb)
 

|